Recently, many electricians have installed arc fault breakers in order to comply with the 2002 NEC code stating that all branch circuits supplying bedrooms in single family and multi-family dwellings shall be protected by an arc fault circuit breaker. Until now, there has been no method of testing such breakers. The AFI-100 provides a reliable, versatile solution. In addition to providing pass/fail verification on arc fault breakers, it also performs polarity and pass/fail verification on GFI receptacles and breakers. UL approved.
Allows instant testing of AFCI breakers.
May be used in testing GFCI receptacles or GFCI circuit breaker protected circuits.
LED indicators signal correct wiring, open ground, open neutral, hot/ground reversed, and hot/neutral reversed.
Easy one-button test.
Simulates parallel arcing condition to test AFCI operation.
Microprocessor-controlled precision circuitry.
Impact-absorbing housing for extra durability.
No batteries.
Approved per UL 1436 Outlet Circuit Tester.
Specifications:
Arc Fault Test: (12) 112 A pulses
Pulse Width: 400΅s
Repetition Rate: 120 Hz
Ground Fault Test: 7 mA at 120 VAC
Polarity Indicator: 3 LED's indicate proper wiring to outlet being tested
Power: 120 VAC, 15 A or 20 A branch circuit
Lifetime Limited Warranty.
Mfr. Part No.
AFI-100
|